Intel(R) Server System S7000FC4UR System software update package for 
Intel(R) Deployment Assistant, Intel(R)One Boot Flash Update Utility, 
The embedded EFI Shell, Windows* Preboot Execution Environment 
================================================================================
Intel Enterprise Platform & Services Division - Marketing
Intel Corporation
2800 Center Drive, DuPont, WA 98327 USA
================================================================================
DATE    : Dec 10, 2008
TO      : Intel(R) Server System S7000FC4UR customers
SUBJECT : Release Notes for system software update package 

This package can be used with:
 - Intel(R) Deployment Assistant
 - Intel(R) One-boot Flash Update (OFU) v9.62 or later)
 - The embedded EFI shell
 - Windows* Preboot Execution Environment (WinPE)
================================================================================
                              ABOUT THIS RELEASE
================================================================================
BIOS   : SFC4UR.86B.01.00.0027   Build Date : November 18, 2008
BMC    : v00.19
FRUSDR : 14  
HSC    : v02.09
================================================================================
                           SUPPORTED PLATFORMS And Dependency
================================================================================
Intel(R)Server System S7000FC4UR.
Processors supported: Intel(R) Xeon(R) Processor 7200 Series 
                      Intel(R) Xeon(R) Processor 7300 Series
                      Intel(R) Xeon(R) Processor 7400 Series  
    
Microcode update versions: CPUID 06FBh;   Version B6; Status Production;
                                 06D1h;   Version 21; Status Production;

On-Board Component Option ROM Versions:
ATI* RN50 VGA                 : BK-ATI VER008.005.031.000BR yj24657a.cfg v611 
ESB2 AHCI Option ROM          : iSrc 1.08 09252006
ESB2 SATA SW-RAID Option ROM  : vA.01.06131709I
ESB2 iSCSI Boot Option ROM    : v2.0.07
82564EB PXE Ver.              : Intel(R) Boot Agent GE v1.2.60
82575EB PXE Ver.              : Intel(R) Boot Agent GE v1.2.60
ESB2 BSU Revision             : 1.01
CNB BSU                       : v0.83
Memory Reference Code Version   : CNB MRC v1.2 RC1

================================================================================
                  System Firmware Update Package Usage Instructions                  
================================================================================
This package can be updated using one of the following methods:
 - The embedded EFI shell
 - Intel(R) Deployment Assistant
 - windows or Linux operating system using Intel(R) One-boot Flash Update (OFU)   
 - Windows* Preboot Execution Environment (WinPE)

EFI Shell

User can update system firmware from Intel server EFI shell with below
steps
- Download Intel server system firmware update package from support.intel.com
- Unzip package and copy all files to a folder in a USB disk key 
- Insert USB disk key to server USB port
- Reboot server to EFI shell
- Run command " map -r " at EFI shell to mount USB disk key
- Run command " fs0:" to change folder to USB disk key, USB key may also mount to
  fs1:. The number of "fs" is dependent on the result of command "map -r"
- Change folder to the folder that store the firmware package
- Run command " startup.nsh " to start firmware update process

Please refer " EFI_Instructions.pdf " 
in this firmware package for the details of EFI commands 

Intel(R) Deployment Assistant (IDA)

User can use IDA CD to update system firmware with below steps
- Boot server with IDA CD
- Select " Get System Updates " Button at IDA home page
- IDA has three options to get system firmware update package

  . From support.intel.com
    IDA can automatically download system firmware update package from Intel
    supporting web site. 
    Server should have valid Internect conncetion. User can follow the indication
    on IDA GUI to enter local server IP setting and Internect proxy configuration;
    Select "Next" button to start firmware download and update process
    
  . From my network
    IDA can get system firmware update package from a Windows* share folder on LAN.
    User need to download firmware update package from support.intel.com web site
    and copy to a Windows* share folder first;
    Follow the indication on IDA GUI to enter local server IP setting / 
    Windows* file server name / Windows* account name and its password;
    Find the firmware update package in the Windows* share folder from 
    a IDA pop-up window;
    Select "Next" button to start firmware update process
          
  . From USB Disk on key or Hard Disk
    IDA can get system firmware update package from USB storage also.
    User need to download firmware update package from support.intel.com web site
    and copy it to a USB key and insert into server USB port;
    Select option "From USB disk on key or hard disk" and select "Browse" button;
    Select firmware update package ZIP file in a IDA pop-up window;
    Select "Next" to start firmware updating
    
 Note: system firmware update package is .ZIP file format, it doesn't need to
       unzip, directly copy the .ZIP to Windows* share folder or USB disk


Intel(R) One Boot Flash Update Utility

The Intel(R)One-Boot Flash Update Utility (Intel OFU) is used to update the BIOS 
and firmware on the Intel server boards while the operating system is running. 
The utility may be launched from a command prompt in either the Windows*
or Linux* Operating Systems.
User can get Intel OFU from Server system IDA CD or from support.intel.com web site
Please refer Intel OFU user guide about the details of intatllation and usage of OFU

User can use OFU to update system firmware with below steps
- Install OFU on Windows* or Linux* system
- Download Intel server system firmware update package from support.intel.com 
- Unzip package and copy all files to a folder in Windows* or Linux* system
- Run below command in Windows* connamd line window or Linux* terminal windows 
  <OFU install folder name>:\ flashupdt -u  <package folder name>\flashupdt.cfg
  to start firmware update process
                  

Windows* Preboot Execution Environment (WinPE)

This Intel server system firmware package can be inserted to Windows* PE customized
image and create a bootable Windows* PE CD. 
User can update system firmware from WinPE CD with below steps
- Boot server with customized WinPE CD
- Run script "WinPE_Update.bat" in this firmware package in customzied WinPE CD 
  to start firmware update process
  
Please refer white paper "White Paper-Intel Server Utilities Procedure for WinPE.pdf"
in this firmware package for detailed steps of building customized WinPE CD   


================================================================================
                              BIOS Changes since release
================================================================================
BIOS R27 fixed below issues
-   L1 and L2 Cache size is wrong on E7420 Processors.
-   BIOS setup is slow with four 7400 series Processors.
-   USB mouse and keyboard detected if USB is disabled
-   WinPE boot issue from USB flash disk.	
-   System displays ES1000 BIOS message during pOST and 
-   Event log in windows Displays PPM disabled Error Event
-   CPU signature in MP configuration Table is incorrect for 7400 serises processors
-   Extended Table Checksum in MP Configuration Table Header is incorrect
-   State Hint is Disabled as per Wolfdale BWGo.92 on 7400 seires processors.
-   StopGrant Ack Count is incorrectly Programming for 7400 seires processors.
-   PECI feature was enabled incorrect on 7400 series Processor.
-   MCH BIOS Spec Update rev0.83

BIOS R25 fixed below issues 
- Sony AD-7560A DVD drive did not consistently appear in the BIOS setup 
- Unable to update SAS Riser to HW RAID using Dual Mode Firmware Update 
- L3 cache not displayed in BIOS setup and SMBIOS.
- Fatal error injected on slot1-6 did not generate Windows 2008 crash"
- Intel(R) Xeon(R) Processor 7400 series CPUID reporting only lower 16 bits in BIOS Setup 
- Thermal margin sensors not working with Intel(R) Xeon(R) Processor 7400 serious setup. 
- Fix for SelfTest Tool failures PCI-e to PCI-X Bridge, Cache Line Size
- POST screen hand incorrectly displayed line while BMC jumper is in force update mode.
- L3 cache size BIOS setup shown as "0" for some Intel(R) Xeon(R) 7400 series Processors.
- Added Setup option to enable/disable USB device promoting to top of Boot Order.
- Modify behavior of Global Fault LED for correctable errors

BIOS R23 fixed below issues 
- Removed the Dummy DSDT Table support for OA2.0.
- Fixed blue screen death issue when install Windows* server 2008 EM64T
- Corrected BOIS ACPI issue
- Added feature to prevent Legacy OS redirection in EVGA mode
- Resolved the problem of WHQL Sleep test(Hibernate) failure
- Resolved the problem of WHQL TCG TPM Integration test failure
- Corrected the issue of PCIE slot 7 slowdown from X4 to X1
- Resolve the issue of performace of Quad Core Intel(R) Xeon(R) Processor 7300 
  Series drops sharply
- Fixed the copyright problem on BIOS POST screen
- Corrected the issue that date is shown incorrectly after 2008.1.1
- Fixed the voltage issue in SMBIOS Type 4
- Fixed the issue that Intel(R) Deployment Assistant CD may fail to boot up
- corrected the issue of BIOS admin password can't be set on 501 board
- Corrected SMBIOS Type 17 DIMM size for Memory Board A and B DIMM 1 
- Corrected DIMM LED behavior when memory RAS is disabled and an uncorrectable error occurs.
- Corrected IOAT is disabled at MFG mode 
- Corrected an WHEA error record issue.
- Corrected inconsistent SEL entries when memory mirroring is set and an uncorrectable error occurs. 
- Added support for Microsoft* Windows* 2003 network installation with the SAS riser. 
- SAS Riser OPROM can be entered during POST now.
- Corrected support for Adaptec* ASC-29320LPE adapter so it will complete POST in slot 7.  
- Corrected the problem of unable to enter LSI* 1078 SAS RAID Web BIOS interface by pressing [Ctrl]+[H]
- Corrected an WHEA error record issue.
- Per Chipset BIOS Specification Update: Added support for Documentation Changes #2.
- Per Chipset BIOS Specification Update: Snoop Filter enable/disable was removed from BIOS setup.


================================================================================
                              BMC Changes since release
================================================================================
BMC FW19 fixed below issues
- Fab 5 memory baord will repalce AT24C02 FRU EEPROM with PCA9500 device which has integrated 2Kbit EEPROM for FRU and GPIO's

BMC FW18 fixed below issues
- Fixed reliability problem of ESB2 BMC on Windows* server 2003
- Fixed ESB2 BMC boot failure issue
- Corrected the issue that NMI button can not trigger Windows* server 2003 to 
generate memory dump file

BMC FW17 fixed below issues
- Corrected erroneous SEL Logs of power units redundancy during AC Power Cycling
- Corrected false events of power supply temperature  
================================================================================
                              FRUSDR Changes since release
================================================================================    
FRUSR14:
- Resolved issue of SMBIOS HCT Test fails on FRU error
================================================================================
                              HSC FW Changes since release
================================================================================
S7000FC4UR 4U 2.5" SAS HSC v2.09:
- HDD fault LED does not turn on correctly 

S7000FC4UR 4U 2.5" SAS HSC v2.08:
- Corrected HSC Fault LED and Locate feature 
   
================================================================================
                           LEGAL INFORMATION
================================================================================

Information in this document is provided in connection with Intel Products
and for the purpose of supporting Intel developed server boards and systems.
No license, express or implied, by estoppel or otherwise, to any intellectual 
property rights is granted by this document. Except as provided in Intel's 
Terms and Conditions of Sale for such products, Intel assumes no liability 
whatsoever, and Intel disclaims any express or implied warranty, relating to 
sale and/or use of Intel products including liability or warranties relating 
to fitness for a particular purpose, merchantability, or infringement of any 
patent, copyright or other intellectual property right. Intel Corporation 
may have patents or pending patent applications, trademarks, copyrights, or
other intellectual property rights that relate to the presented subject matter.
The furnishing of documents and other materials and information does not 
provide any license, express or implied, by estoppel or otherwise, to any such
patents, trademarks, copyrights, or other intellectual property rights.  
Intel products are not intended for use in medical, life saving, or life 
sustaining applications. Intel may make changes to specifications and product
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation. 

*Other names and brands are the property of their respective owners.

Copyright (C) 2008 Intel Corporation.
================================================================================


[END OF RELEASE NOTES]