***             mBMC Firmware Update & Configuration Utility              ***
***                                                                       ***
*****************************************************************************
*****************************************************************************

1. Please put all files in the same directory.

2. Run "ACER.bat" at DOS.




Revision History
====================

2004-03-29
   1) Set CPU temperature thresholds: 85C for warning, 90C for critical.
   2) Set SDR version as v1.06.
   3) Configure content of FRU as Acer's requirement.
   4) Set FRU version as v1.06.
   5) Set whole version as v1.06. 

2004-03-19
   1) Set new voltage thresholds as Acer's request.
   2) Remove VccP, VTT_MCH, 12V_1 sensors.
   3) Set versions of SDR, PEF, FRU as v1.05.
   4) Set whole version as v1.05.

2004-02-25
   1) Set default IP = 0.0.0.0
   2) Set version as v1.04.
   3) Update "acer.bat" and files accordingly.

2004-02-24
   1) Get rid of mBMC firmware update and eeprom update from the package
      per Acer's request.
   2) Update "acer.bat" and files accordingly.

2004-02-20
   1) Ignore LAN leash lost events
   2) Set version as v1.03

2004-02-19
   1) Change VTT_MCH threshold setting.
   2) Set version as v1.02

2004-02-19
   1) Change MVTT(1.3V) threshold setting.
   2) Set version as v1.01

2004-02-18
   1) Store version string into mBMC internal flash.
   2) Set OEM version string as "TAMB".
   3) Version, starting from v1.00, contains major and minor numbers. 
   4) Rename "CFG0214.bat" to "CFG.bat", "SDR0214.bat" to "SDR.bat", 
      "PEF0204.bat" to "PEF.bat" and "FRU0213.bat" to "FRU.bat".
   5) Incorporate the content of "LAN0210.bat" with "CFG.bat".
   6) Disable logging IPMI PET generated events in SEL memory. 
  
2004-02-14
   1) New "CFG0214.bat" which disables SMBus alert isolation of mBMC is
      added.
   2) New Lan EEPROM file "11000213.eep" is added. 
   3) Change VccP range to support voltage from 1.25v to 1.525v.
   4) Set version number as 0x03.

2004-02-13
   1) Modify "fru0209.bat" for correcting checksum error and save it as
      "fru0213.bat".

2004-02-12
   1) Change formula of CPU fan and system fan. New formula can represent 
      lower fan speed.
   2) Set upper thresholds of CPU fan and system fan as F0h, which are about 
      760 rpm.
   3) Set version number as 0x02.
   4) Add "CLEARSEL.BAT" to clear sel.

2004-02-11
   1) Change byte 14, event/reading type codes, of Thermal Trip, Processor 
      Hot, and VR Hot to 70h.
   2) Change byte 15:16, assertion event mask/lower threshold reading mask 
      of Thermal Trip, Processor Hot, and VR Hot to 0001h.
   3) Change byte 17:18, deassertion event mask/upper threshold reading 
      mask of Thermal Trip, Processor Hot, and VR Hot to 0001h.
   4) Change byte 19:20, discrete reading mask/settable threshold mask, 
      readable threshold mask, of Thermal Trip, Processor Hot, and VR Hot 
      to 0001h.

2004-02-10
   1) Add version control. Put version number in byte 47 of 
      1st type-01-SDR (full SDR). Version number starting 0x01.
   2) Change mBMC firmware chicking utility to v1.03
   3) Change "readme.1st" to "release".
   4) Add file list (files) and list all versions of files.
   5) Change default IP address as "192.168.1.1".
   6) Remove "lanupd.exe".
   7) Move mBMC firmware codes (.hex) from .\fwhex to based directory.
   8) Remove "fwupdate.exe".

2004-02-09
   1) Change mBMC default password as "admin@acer".
   2) Add mBMC firmware-checking function to check product ID.

2004-02-04
   1) Change mBMC default password as "acer".
   2) Add PEF action -- send alert.
   3) Add warning thresholds for temperature sensors and voltage sensors.
   4) Add mBMC firmware-checking function for firmware version in the
      configuration file.