Array Rebuild:
Click on Rebuild to rebuild the array. Rebuilding is available only for RAID 1 (Mirror) and RAID 10 arrays. The Rebuild operation automatically determines the best available source physical drive and sets a spare drive as a target drive, another drive in this array will be marked as Failed and shifted to Spare drive pool.. The rebuild operation will not be performed unless a spare drive is available or other member of array is in Rebuilding state. After you click on Rebuild the following options display in the right frame. They are described below.
|
Field |
Description |
|
Rebuild All Partitions |
Place a check in this box to rebuild all the partitions. This is checked by default. |
|
Stop on Error |
Place a check in this box to Stop the rebuild if an read/write error is discovered during this operation. This is checked by default. |