Distributed Processing Technology Corp.

Installation Notes for Novell NetWare I2O Device Drivers
January 6, 2000
*********************************************************************

This information applies to Novel NetWare versions 4.11, 4.2 and 5.
The following sections describe procedures for installing DPT-supplied
I2O device drivers for Novell NetWare. These device drivers are
produced by Novell and tested by DPT for compatibility with DPT
SmartRAID V and VI controllers.

Two installation scenarios are described for each version of NetWare:

  Initial Installation
  Adding to an existing system

The final section describes the procedure for installing remote communication
support for DPT Storage Manager.

NOTE:  The drivers for NetWare 4.11 are available as a download from
       the DPT Technical Support web site. These files are not
       included on the DPT NetWare diskette. The file is compressed in
       ZIP format. Download the file and unzip the contents to a
       floppy disk, then follow the installation procedure for NetWare
       4.11.

-----------------------------------------------------------
NetWare 4.11

Initial Install

    1.  Ensure that you are using a CD-ROM drive that is not attached
        to the DPT controller.

    2.  Install the DPT controller.

    3.  Create a 750MB DOS partition on your disk drive you will
        be using to boot NetWare and install DOS and be sure the
        appropriate CD-ROM drivers are copied to the root directory.

    4.  Boot DOS and run A:\DPT411.BAT from the floppy disk you created.

    5.  Run INSTALL from C:\

    6.  Choose I2OPCI.NLM and BKSTROSM.HAM as disk drivers.

        Verify that your STARTUP.NCF lists BKSTROSM.HAM after
        I2OPCI.NLM before you restart the server.

    7.  Install the latest NetWare4 Patch kit.

Adding to an Existing System

    1.  Install the latest NetWare4 Patch kit.
        
    2.  Install the DPT controller.

    3.  Boot the server and insert the DPT NetWare diskette in the
        floppy disk drive.

    4.  Start INSTALL.NLM

        Select Install Product and then select Install Product Not
        Listed. Install I2O support and Block Storage support only.

-----------------------------------------------------------
NetWare 4.2

Initial Install

    1.  Ensure that you are using a CD-ROM drive that is not attached
        to the DPT controller.

    2.  Create a directory named NWUPDATE on the C: drive

    3.  Copy the contents of A:\NWCOMMON and A:\NW42 from the DPT
        NetWare diskette to C:\NWUPDATE.

    4.  When prompted choose I2OPCI.NLM and BKSTROSM.HAM as disk
        drivers.

    5.  Verify that your STARTUP.NCF lists BKSTROSM.HAM after
        I2OPCI.NLM before you restart the server.


Adding to an Existing System

     1.  Install the DPT controller.

     2.  Boot the server and insert the DPT NetWare diskette in the
         floppy disk drive.

     3.  Start INSTALL.NLM

         Select Install Product and then select Install Product Not
         Listed. Install I2O support and Block Storage support only.


-----------------------------------------------------------
NetWare 5

Initial Install

    1.  Ensure that you are using a CD-ROM drive that is not attached
        to the DPT controller.

    2.  Create a directory named NWUPDATE on the C: drive

    3.  Copy the contents of A:\NWCOMMON from the DPT NetWare diskette
        to C:\NWUPDATE.

    4.  When prompted choose I2OPCI.NLM and BKSTROSM.HAM as disk
        drivers.

    5.  Verify that your STARTUP.NCF lists BKSTROSM.HAM after
        I2OPCI.NLM before you restart the server.

    6.  Install the latest NetWare 5 patch kit.

Adding to an Existing System

     1. Install the DPT controller.

     2. Boot the server and insert the DPT NetWare diskette in the
        floppy disk drive.

     3. Use NWCONFIG.NLM and select Driver, then select Disk Driver 
        and install I2OPCI.NLM and BKSTROSM.HAM as the drivers.  

     4. Verify that your STARTUP.NCF lists BKSTROSM.HAM after
        I2OPCI.NLM before you restart the server.

-----------------------------------------------------------
Remote Communication Support for Storage Manager

     1. Insert the DPT NetWare diskette in the floppy disk drive.

     2. Enter the following command at the prompt:

          LOAD A:\DPTINST.NLM.

     3. You will be prompted to choose whether to load the remote
        communication support immediately or delay loading until the
        server is restarted.

        If you choose to wait until the server restarts, you will not
        be able to monitor the DPT subsystem from a remote client
        until the server is shut down and restarted. Otherwise, the
        remote communication support is loaded and available as soon
        as you exit the install program.

<End of install notes for DPT NetWare support>